Sign In | Join Free | My vivirlatino.com
vivirlatino.com
Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
EK keeps looking for valuable distributors and partners around international markets…
Home > Air Cooled Modular Chiller >

Eco Friendly 134kW Refrigerant Air cooled Modular Chiller Heat Pump Unit

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

Eco Friendly 134kW Refrigerant Air cooled Modular Chiller Heat Pump Unit

Brand Name : Euroklimat
Model Number : EKAC460BR1
Certification : AHRI ,CE,ISO9001,ISO14001,OHSAS18001
Place of Origin : China
MOQ : 1pcs
Price : negotiation
Payment Terms : T/T or western Union
Supply Ability : 3,000pcs per month
Delivery Time : 10 working days after received your payment
Packaging Details : Packed in carton firstly,and then reinforced with wooden case for outer packing
COP : 3.35
Refrigerant : R410A
Heating Capacity : 142-2272kW
Cooling Capacity : 134-2144 kW
Number Of Modules For A Modular Unit : 16 pcs Units
Test Center : The EK Test Center Has Been Approved By The China National Accreditation Service For Conformity Assessment (CNAS).
Contact Now

Environmentally-Friendly Refrigerant-Type Modular Air-Cooled Heat Pump Unit


Specifications:


Technical data sheet


Model EKAC 460B1EKAC 460BR1EKAC 920B1EKAC 920BR1EKAC 1380B1EKAC 1380BR1
Combination methodMasterEKAC 460B1MEKAC 460BR1MEKAC 460B1MEKAC 460BR1MEKAC 460B1MEKAC 460BR1M
Slave----EKAC 460B1SEKAC 460BR1S2EKAC 460B1S2EKAC 460BR1S
Nominal refrigerating capacitykW138138276276414414
USRT39.2439.2478.4878.48117.72117.72
x104
kcal/h
11.8711.8723.7423.7435.6135.61
x104
Btu/h
47.1047.1094.294.2141.3141.3
Nominal heating capacitykW--148--296--444
USRT--42.08--84.16--126.24
x10
4kcal/h
--12.73--25.46--38.19
x104
Btu/h
--50.51--101.02--151.53
Total power consumption under nominal refrigerating capacitykW40.840.881.681.6122.4122.4
Total power consumption under nominal heating capacitykW--42.5--85.0--127.5
Power supply 380 V/3N~/50 Hz
RefrigerantType R410A
Control Electronic expansion valve
CompressorType Full hermetic scroll compressor
Lubricant Lipid oil (POE-160SZ)
Qty.Piece224466
FanType Axial large-blade low-noise fan
Qty.Piece224466
Water-side heat exchangerType High-efficiency vacuum brazed heat exchanger
Refrigerating water flow ratem3/h23.723.747.447.471.171.1
Heating water flow ratem3/h25.5h25.550.950.976.476.4
Water resistancekPa424242424242
Recommended length of inlet/outlet water pipeinch≥3≥3≥4≥4≥5≥5
Power wireCross- sectional area of main wiresmm235359595185185
Qty. of main wires 3
Cross- sectional area of neutral wiremm2610
Qty. of neutral wires 1
Cross- sectional area of ground wiremm2161650509595
Qty. of ground wires 1
DimensionsL x Hmm2200×2260
Wmm115011502900290046504650
Weight of unitNet weightkg99010201980204029703060
Weight of unit during runningkg100510352010207030153105

Model EKAC1840B1EKAC1840BR1EKAC2300B1EKAC2300BR1
Combination methodMasterEKAC460B1MEKAC460BR1MEKAC460B1MEKAC460BR1M
Slave3EKAC460B1S3EKAC460BR1S4EKAC460B1S4EKAC460BR1S
Nominal refrigerating capacitykW552552690690
USRT156.96156.96196.2196.2
x104
kcal/h
47.4847.4859.3559.35
x104
Btu/h
188.4188.4235.5235.5
Nominal heating capacitykW--592--740
USRT--168.32--210.4
x10
4kcal/h
--50.92--63.65
x104
Btu/h
--202.04--252.55
Total power consumption under nominal refrigerating capacitykW163.2163.2204204
Total power consumption under nominal heating capacitykW--170.0--212.5
Power supply  
RefrigerantType  
Control  
CompressorType  
Lubricant  
Qty.Piece881010
FanType  
Qty.Piece881010
Water-side heat exchangerType  
Refrigerating water flow ratem3/h94.894.8118.5118.5
Heating water flow ratem3/h101.8101.8127.3127.3
Water resistancekPa42424242
Recommended length of inlet/outlet water pipeinch≥6≥6≥6≥6
Power wireCross- sectional area of main wiresmm2240240185185
Qty. of main wires  6
Cross- sectional area of neutral wiremm2 
Qty. of neutral wires  
Cross- sectional area of ground wiremm2120120185185
Qty. of ground wires  
DimensionsL x Hmm 
Wmm6400640085108510
Weight of unitNet weightkg3960408049505100
Weight of unit during runningkg4020414050255175

Notes:
■ Working conditions of the unit for testing the nominal refrigerating capacity: Outlet temperature: 7°C; water flow rate: 0.172 m3/(h•kW); outdoor temperature: 35°C
■ Working conditions of the unit for testing the nominal heating capacity: Outlet temperature: 45°C; water flow rate: 0.172 m3/(h•kW); outdoor psychrometric difference: 7°C or 6°C
■ Water resistance includes differential water pressure of the unit and that of the affiliated Y-shape filter.
■ For combined units, the manufacturer does not offer general water pipes and they must be prepared and installed on site. Diameter of the pipes should comply with design standards.
■ A modular unit can be combined by same or different modules based on actual requirements; up to 16 modules can be built into a modular unit. The parameters listed in the table above are
for commonly combined units.
■ Power distribution and wiring are subject to unit nameplates or installation guide.


Description:


1, The innovative EK air conditioner adopts the leading air-cooled heat pump design in Europe which enables an energy efficiency ratio (EER) in full load mode exceeding Chinese energy-saving product certification standard (higher than COP3.2).

2, EKAC460BR1 series air-cooled modular unit adopts R410A. Compared with the conventional refrigerant R22, R410A does not contain chlorine and therefore has no adverse impact on the ozonosphere. It serves as a medium- and long-term substitute of R22.

3, RoHS-certified environmentally-friendly zinc-plated steel boards are adopted to ensure an endurable body which is resistant against corrosion, peeling, and fading.

4, The ring-shape return air heat exchanger enables more evenly air flow and higher efficiency.

5, The electric control cabinet is covered with sheet metals both internally and externally. All internal elements are internationally renowned brand products..

6, The 500-level PMV electronic expansion valve ensures precise flow control. Degree of superheat can be precisely matched when the unit’s load changes.

7, A dual-speed condenser fan with blades passing the dynamic and static balance test is driven by a high-efficiency motor to realize efficiency and quietness at night..

8, The compressor uses internationally leading technologies, including axial end sealing technology, radial oil membrane sealing technology, and new electronic protection technology. The large oil pool and the gigantic space at the absorption side, together with the liquid-gas separation function, ensure large charging capacity.

9, The dual-system plate heat exchanger can bear up to 3.0 MPa pressure at the water side, applicable to water systems of super-high buildings.

10, The LOVATA inner grooved copper tube ensures reliable quality and high heat exchange rate.

11, The unit adopts anti-vibration design and multi-level noise reduction. The brand quiet full-hermetic scroll compressor; dual-speed quiet motor; blades passing the dynamic and static balance test ensures industry leading noise reduction grade and anti-vibration degree.

12, Lower-part hermetic structure: The lower part of the unit is covered with sheet metals to insulate noise of a running compressor.

13, An innovative smart silence mode is adopted. The fan speed (high/low gear) can be automatically adjusted based on unit’s running state and ambient temperature to allow a unit to work in quiet and low-noise mode. The noise at night is reduced by 6 dB (A).

14, The EK test center has been approved by the China National Accreditation Service for Conformity Assessment (CNAS). By national-level test (with respect to corrosion, fatigue, frequent startup, etc), the modular unit is highly reliable.

15, Defrosting conditions are automatically to save energy. Defrosting capability varies depending on the amount of frost, to maximize normal heating time and minimize temperature change caused by defrosting.

16, The EK system can be composed of up to 16 modules. Any slave module of the system can take over works of a faulty master module, posing no adverse impact on the entire system. Besides, a part of load of the EK system is born alternately to balance load of the compressor.

17, A modular un


Product Tags:

air source heat pump

      

heat pump outside unit

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Eco Friendly 134kW Refrigerant Air cooled Modular Chiller Heat Pump Unit Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0